• Induskey INK295 Low Range Turbidity
  • Induskey INK295 Low Range Turbidity

Induskey INK295 Low Range Turbidity

No.INK295
The Induskey INK295 is a professional online low‑range turbidity analyzer for continuous water quality monitoring. Adopting the 90° light scattering principle, it delivers high‑precision measurement in the 0–10 NTU range with 0.001 NTU resolution. Equipped with an automatic optical window cleaning brush and built‑in anti‑bubble system, it ensures stable long‑term operation and greatly reduces manual maintenance. Supporting RS485 MODBUS communication and factory pre‑calibration, the INK295 enables plug‑and‑play deployment. It is widely used in drinking water treatment, distribution networks, pure water systems, source water monitoring, and other low‑turbidity water applications.
  • Induskey INK295 Low Range Turbidity

Description

INK295 Low Range Turbidity Analyzer Comprehensive Analysis
1. Product Overview

The Induskey INK295 is a high-precision online low-range turbidity analyzer purpose-built for continuous, real-time monitoring of drinking water and ultra-clean water quality. Engineered with the industry-standard 90° light scattering principle, it delivers ultra-low detection thresholds, exceptional measurement accuracy, and minimal maintenance requirements over its entire operational lifespan.

Equipped with an integrated automatic cleaning brush and a self-developed defoaming unit, the analyzer eliminates bubble interference and optical window fouling, ensuring long-term stable operation in demanding water treatment environments. Factory pre-calibrated with built-in parameters, it supports plug-and-play deployment, and features RS-485 MODBUS communication for seamless integration into industrial monitoring systems. It is ideal for low-turbidity scenarios including drinking water treatment, water distribution networks, membrane filtration, and source water monitoring.
2. Sensing Technology & Self-Cleaning System

Sensing Technology

The INK295 operates on the 90° nephelometric light scattering principle, the global gold standard for low-range turbidity measurement. A calibrated infrared light source emits a stable beam into the water sample; suspended particles in the water scatter the light at a 90° angle relative to the incident beam. The intensity of the scattered light is directly proportional to the turbidity (NTU) of the water, which is detected by a high-sensitivity photodiode and converted to a digital signal.

A self-developed optical path and real-time compensation algorithm further enhance measurement precision, minimizing background noise and environmental interference to achieve ultra-high resolution (0.001NTU) in low-turbidity conditions.

Self-Cleaning & Anti-Bubble System

• Integrated Cleaning Brush: The built-in light window cleaning brush automatically removes biofouling, sediment, and contaminants from the optical surface, eliminating measurement drift, extending maintenance intervals, and ensuring long-term stable online monitoring.

• Self-Developed Defoaming Unit: The dedicated defoaming and measuring unit effectively eliminates water bubbles in the flow path, ensuring a stable water inlet and consistent, reliable measurement data even in aerated water systems.
3. Key Features & Competitive Advantages

Core Key Features

1. 90° Light Scattering Measurement: Adopts the internationally standardized 90° scattering method, ensuring traceable, accurate low-range turbidity measurement compliant with global water quality standards.

2. Ultra-Low Range & High Precision: 0-10NTU standard range (customizable ranges available), 0.001NTU resolution, and ±0.01NTU or ±2% accuracy, tailored for ultra-clean water monitoring.

3. Automatic Self-Cleaning System: Integrated optical window brush reduces manual maintenance, extending service life and ensuring long-term stability.

4. Built-In Anti-Bubble Technology: Self-developed defoaming unit eliminates bubble interference, guaranteeing stable water inlet and reliable data.

5. Factory Pre-Calibrated: Pre-loaded calibration parameters enable plug-and-play installation, eliminating complex on-site calibration.

6. Industrial Communication: Supports RS-485 output with MODBUS protocol, compatible with PLC, SCADA, and industrial control systems.

7. Low Power Consumption: Operates at 0.4W (non-wiping) / 1W (wiping) with 12-24V DC power, suitable for energy-efficient monitoring systems.

8. Robust Material Construction: PC+ABS water channel and 316L+POM sensor housing ensure corrosion resistance and durability in harsh water environments.

Competitive Advantages

• Superior Low-Range Performance: Ultra-high resolution and accuracy outperform general-purpose turbidity sensors, making it the ideal choice for drinking water and pure water applications.

• Low Maintenance Design: Automatic cleaning and anti-bubble systems drastically reduce operational costs and manual intervention.

• Plug-and-Play Deployment: Factory calibration and standard industrial interfaces enable fast, easy integration into existing systems.

• Customizable Flexibility: Adjustable measurement ranges and flow compatibility adapt to diverse water treatment pipeline configurations.
4. Technical Specifications
Parameter Specification
Model INK295
Product Type Low-Range Turbidity Analyzer
Measurement Principle 90° Light Scattering Method
Measurement Range 0-10NTU (Other ranges customizable
Accuracy ±0.01NTU or ±2% (take the bigger one)
Resolution 0.001NTU
Working Temperature 0-50°C
Power Consumption 0.4W (non-wiping), 1W (wiping)
Suggested Power Supply DC 12-24V, >1A
Sensor Interface RS-485, MODBUS Protocol
Flow Range 180-500mL/min
Sensor Size Φ54.6mm×193.5mm
Maintenance Light Window Cleaning Brush
Pipe Connection Inlet: 2 Points PE Pipe, Drain: 3 Points PE Pipe
Housing Material Water Channel: PC+ABS; Sensor: 316L+POM
Calibration Factory Pre-Calibrated, Built-in Parameters
Note All parameters tested under laboratory standard liquid conditions


5. Applications

1. Drinking Water Treatment Plants: Continuous monitoring of raw water, filtered water, and finished water turbidity to ensure compliance with drinking water quality standards.

2. Water Distribution Networks: Real-time monitoring of terminal pipe network water quality, detecting turbidity changes to prevent secondary pollution.

3. Membrane Filtration Processes: Turbidity monitoring in RO/UF membrane systems to protect membrane components and optimize filtration efficiency.

4. Source Water Monitoring: In-situ monitoring of river, lake, and reservoir source water turbidity for early water quality deterioration warning.

5. Secondary Water Supply Systems: Turbidity monitoring in residential and commercial secondary water supply systems to ensure water quality stability.

6. Swimming Pools & Water Parks: Continuous monitoring of pool water turbidity to maintain hygiene and safety standards.

7. Industrial Pure Water Systems: Low-range turbidity monitoring in semiconductor, pharmaceutical, and electronic industry pure water production lines.

8. Water Reuse Projects: Turbidity monitoring in recycled water systems to meet reuse quality requirements.