1. Product Overview
The IndusKey IK1107 is a solenoid piston pump designed for precise low-flow water transfer at 25°C, delivering 50–200 cc/min at zero back-pressure with an operating window of 0 < P < 2.5 bar. Carrying VDE, ETL and CQC approvals with Class H insulation, the IK1107 is specified for 100% duty and is built for global appliance markets with three coil voltage versions (220–240VAC, 120VAC and 100VAC).
The electromagnetic piston mechanism provides quiet, pulse-free metering for water dosing systems, laboratory fluid transfer, small appliance water supply, humidifier feed and coffee/beverage equipment. Compact in size (approx. 74 × 27 × 22 mm) with push-fit inlet/outlet ports and a built-in diode for spike suppression, the IK1107 integrates directly into OEM equipment without additional drive electronics.
2. Working Principle
The IK1107 is a solenoid-driven piston pump:
-
Electromagnetic reciprocation — The AC coil alternately attracts and releases the armature at line frequency (50/60 Hz), reciprocating the piston inside the pump chamber.
-
Draw and discharge — Each stroke draws fluid through the inlet check valve and discharges it through the outlet check valve, producing a continuous pulsating flow proportional to stroke frequency.
-
Self-priming — The piston chamber primes automatically at start-up; dry running is permitted only during priming — the pump must not run dry in continuous operation.
-
Thermal design — Class H insulation allows continuous 100% duty at the stated ambient limit (45°C), with laboratory test conditions of 2 min on / 1 min off (Ta 45°C, fluid 35°C).
A suppression diode is built into the coil for electrical noise and spike protection.
3. Key Features & Competitive Advantages
A. Precise Low-Flow Metering
B. Pressure Capability
C. Global Safety Approvals
D. Class H Insulation, 100% Duty
E. Low Noise Operation
F. Three Coil Voltages
G. Maintenance-Friendly Design
H. Compact Footprint
4. Technical Specifications
| Configuration |
|
| Pump Type |
Solenoid (piston) pump |
| Flow Rate (at 0 bar) |
50 / 90 / 150 / 200 cc/min (model dependent) |
| Pressure Range |
0 < P < 2.5 bar |
| Max. Pressure (by model) |
2.0 bar (IK1107-50) · 1.5 bar (IK1107-90) · 1.0 bar (IK1107-150) · 1.0 bar (IK1107-200) |
| Models |
IK1107-50 · IK1107-90 · IK1107-150 · IK1107-200 |
| Ideal Fluid |
Water at 25°C |
| Connection |
Inlet Ø6 mm; outlet Ø6.5 mm (push-fit) |
| Electrical |
|
| Coil Power |
48 W class (see note in Section 7) |
| Coil IK1107-E |
220–240VAC, 50Hz, 48W |
| Coil IK1107-U |
120VAC, 60Hz, 48W |
| Coil IK1107-J |
100VAC, 50/60Hz, 48W |
| Working Mode |
ED 100% |
| Insulation Class |
Class H |
| Diode |
Built into coil |
| Environment & Test |
|
| Ambient Temperature |
45°C max |
| Test Condition |
2 min on / 1 min off; Ta 45°C, fluid 35°C |
| Dry Running |
Permitted only during priming |
| Noise |
12 dBA at 20 cm (per datasheet — see note in Section 7) |
| Approvals |
VDE, ETL, cETL, CQC |
| Mechanical (mm) |
|
| Body (L × H × W) |
73.9 × 27.4 × 22.0 |
| Ports |
Ø5.2 barb (in/out) |
| Mounting tab |
18 mm tab; fixing hole 6.40 × 0.8 |
5. Applications
The IndusKey IK1107 is engineered for OEM low-flow water pumping duties:
-
Water Dosing Systems: Precise chemical or additive dosing in cleaning and treatment equipment.
-
Laboratory Fluid Transfer: Quiet, metered water transfer in analytical and research instruments.
-
Small Appliance Water Supply: Coffee machines, steam irons, garment steamers and beverage dispensers.
-
Humidifier Feed: Continuous feed pumps for residential and industrial humidifiers.
-
Coffee & Beverage Equipment: Metered water delivery for espresso and vending systems.
-
General Low-Flow Pumping: Any 50–200 cc/min water transfer duty requiring certified components and continuous operation.
6. Selection, Ordering & Installation Guidelines
Ordering Codes
-
Pump model (flow / max pressure): IK1107-50 (50cc/min, 2.0bar) · IK1107-90 (90cc/min, 1.5bar) · IK1107-150 (150cc/min, 1.0bar) · IK1107-200 (200cc/min, 1.0bar)
-
Coil / voltage suffix: -E (220–240VAC 50Hz) · -U (120VAC 60Hz) · -J (100VAC 50/60Hz)
-
Example: IK1107-50E = 50 cc/min pump, 220–240VAC coil
Selection
-
Flow vs. pressure: Higher-flow models have lower maximum pressure — select the model whose max pressure covers the system back-pressure at the required flow point.
-
Voltage: Match coil suffix to local supply (E: EU/China 220-240V; U: North America 120V; J: Japan 100V).
-
Fluid: Ideal for water at 25°C; for other fluids or temperatures consult IndusKey.
-
Duty: ED 100% rating suits continuous feed applications; observe 45°C ambient limit.
Installation
-
Orientation: Mount with ports vertical or per mechanical drawing; observe IN/OUT marking.
-
Priming: Fill the inlet line before start-up; avoid dry running beyond the priming phase.
-
Mounting: Use the 18 mm mounting tab with the 6.40 × 0.8 fixing hole; isolate pump from chassis vibration where noise is critical.
-
Wiring: Coil includes built-in diode; connect per approval-compliant wiring practices.
Maintenance