1. Product Overview
The IndusKey IK1103 is a normally closed manifold solenoid valve built on a direct-acting compact design with threaded ports and sub-base connection. Configured with one to four valve positions on a common manifold base, the IK1103 provides independent on/off control of multiple neutral gas or fluid lines from a single compact assembly — ideal where panel space is limited and multiple switching points are required.
The direct-acting construction requires no pilot pressure and supports high cycling rates with low coil temperature rise, while the IP65-rated SA11B coil (9 VA AC / 8 W DC, 100% ED) ensures reliable continuous operation. With orifices of 1.6, 2.5 and 3.0 mm, operating pressure from 0 to 1.0 MPa (zero minimum), port sizes from 1/8" to 1/2" in BSPP/BSPT/NPT/flange/UNF options, and body/seal combinations of brass or stainless steel with NBR, EPDM, PTFE or VITON seals, the IK1103 adapts to a broad range of pneumatic and fluid control duties.
2. Working Principle
The IK1103 is a direct-acting solenoid valve mounted on a shared manifold sub-base:
-
Direct actuation — Energizing any coil directly lifts its armature from the seat; the flow path opens immediately with no pilot stage and no minimum pressure requirement (operates from 0 MPa).
-
Independent stations — Each valve position on the manifold is electrically independent: one to four coils can be energized individually, allowing selective control of multiple lines from one compact assembly with a single common inlet.
-
High-cycle design — The coil and magnetic circuit are optimized for frequent switching with low temperature rise, supporting continuous-duty automation sequences.
-
Sealing — Seal materials (NBR to 80°C, EPDM to 120°C, PTFE, VITON to 150°C) are selected for compatibility with neutral gases and fluids, while the manifold base (aluminum or SUS304) and valve body (brass or SUS304) match the corrosion demands of the application.
The IK1103 is normally closed (NC) — each station opens when its coil is energized and closes by spring return when de-energized.
3. Key Features & Competitive Advantages
A. Multi-Position Manifold
B. Direct Acting — No Pilot Pressure Required
C. High Cycling Capability with Low Temperature Rise
D. Wide Seal Material Selection
-
NBR (−10 ~ +80℃), EPDM (−10 ~ +120℃), PTFE, VITON (−10 ~ +150℃) — matched to neutral gases, water, oils and process fluids.
E. Flexible Materials
F. Broad Port Options
-
Port sizes 1/8", 1/4", 3/8", 1/2" with BSPP, BSPT, NPT, flange or UNF connections.
G. Compact Footprint
H. Low-Power IP65 Coil
4. Technical Specifications
| Configuration |
|
| Valve Type |
2/2-way, direct-acting, manifold solenoid valve |
| Function |
Normally closed (NC) |
| Manifold Positions |
1 / 2 / 3 / 4 valve stations on one base |
| Port Size |
1/8", 1/4", 3/8", 1/2" |
| Connection |
BSPP, BSPT, NPT, flange, UNF |
| Orifice |
1.6 / 2.5 / 3.0 mm |
| Models |
IK1103-16 (1.6mm) · IK1103-25 (2.5mm) · IK1103-30 (3.0mm) |
| Cv Value (by orifice) |
0.11 (1.6mm) / 0.18 (2.5mm) / 0.30 (3.0mm) |
| Performance |
|
| Operating Pressure |
0.0 ~ 1.0 MPa |
| Max. Pressure (1.6mm) |
1.6 MPa (AC) / 1.6 MPa (DC) |
| Max. Pressure (2.5mm) |
1.2 MPa (AC) / 1.2 MPa (DC) |
| Max. Pressure (3.0mm) |
1.0 MPa (AC) / 1.0 MPa (DC) |
| Min. Pressure |
0.0 MPa — no minimum required |
| Medium |
Neutral gases and fluids |
| Medium Temperature (NBR seal) |
−10℃ ~ +80℃ |
| Medium Temperature (EPDM seal) |
−10℃ ~ +120℃ |
| Medium Temperature (VITON seal) |
−10℃ ~ +150℃ |
| Electrical |
|
| Supply Voltage |
DC 12/24V; AC 24/120/240V (60 Hz); AC 110/220V (50 Hz) |
| Voltage Tolerance |
±10% |
| Coil |
SA11B; 9 VA (AC) / 8 W (DC); 100% ED; IP65 (one coil per station) |
| Materials |
|
| Valve Body |
Brass or stainless steel (SUS304) |
| Sub-Base / Manifold |
Aluminum or SUS304 |
| Seals |
NBR / EPDM / PTFE / VITON |
| Armature Tube |
Stainless steel 304 |
| Plunger / Stop |
Stainless steel 430F |
| Springs |
Stainless steel 304 |
| Shading Rings |
Stainless steel 304 |
| Manifold Dimensions (mm) |
|
| Station spacing |
23 mm per station |
| Base width |
30 mm |
| Height |
69 mm |
5. Applications
The IndusKey IK1103 is engineered for compact multi-line control across industrial and laboratory systems:
-
Pneumatic Control Manifolds: Centralized switching of multiple pneumatic lines in automation equipment and control cabinets.
-
Neutral Gas Switching: Independent control of air, nitrogen, CO₂ and other neutral gas lines in process systems.
-
Fluid Control Assemblies: Multi-line switching of water, oil and compatible process fluids on skids and production lines.
-
Instrument Air Systems: Distribution and isolation of instrument air loops in process plants.
-
Laboratory Equipment: Multi-channel gas/fluid switching in analytical instruments, environmental chambers and test rigs.
-
Modular Process Skids: Space-saving valve integration on OEM skids, dosing systems and cleaning equipment.
-
Medical & Analytical Devices: Low-power, compact multi-valve assemblies for compatible neutral media.
6. Selection, Ordering & Installation Guidelines
Model Code System
The full manifold assembly is configured by a 9-field code — example: IK1103-16 GBN SA11B1-2 (1.6mm orifice, 1/8" G-thread, brass body, NBR seal, SA11B coil, AC220V, 2 stations)
| Type |
IK1103 |
Series, NC direct-acting manifold |
| Orifice |
16 / 25 / 30 |
16: 1.6mm · 25: 2.5mm · 30: 3.0mm |
| Port |
1 / 2 / 3 / 4 |
1: 1/8" · 2: 1/4" · 3: 3/8" · 4: 1/2" |
| Thread |
G / N |
G: BSPP · N: NPT |
| Body |
B / S / A |
B: Brass · S: SUS304 · A: Aluminum |
| Seal |
N / P / E / V |
N: NBR · P: PTFE · E: EPDM · V: VITON |
| Coil |
SA11B |
Standard coil per station |
| Voltage |
1–6 |
1: AC220V · 2: DC24V · 3: AC110V · 4: DC12V · 5: AC24V · 6: DC6V |
| Positions |
1 / 2 / 3 / 4 |
Number of valve stations on the manifold |
Note: BSPT, flange and UNF connections are also available — confirm at order.
Selection
-
Function: The IK1103 is normally closed only; each station is electrically independent.
-
Pressure: Operating range 0–1.0 MPa; verify max pressure against orifice size (1.6mm up to 1.6 MPa; 2.5mm up to 1.2 MPa; 3.0mm up to 1.0 MPa).
-
Temperature/medium: Select seal material by medium and temperature: NBR (80°C), EPDM (120°C), VITON (150°C), PTFE for special fluids.
-
Materials: Brass body for general service; SUS304 body and base for corrosive environments; aluminum base for lightweight economy.
-
Stations: Choose 1–4 positions now and extend later — stations are modular on the common base.
Installation
-
Mounting: Bolt the manifold sub-base directly to the panel or machine frame; ensure pipework is clean and deburred before connection.
-
Wiring: Each coil is wired independently per its voltage code; use cable glands to maintain IP65 at each coil.
-
Orientation: Prefer coil-upright installation; observe flow direction per station.
Operation & Maintenance
-
All coils rated 100% ED for continuous energization; low temperature rise supports dense manifold layouts.
-
Periodically verify seal integrity in aggressive media; PTFE or VITON seals extend service intervals.