No.IK1102
Direct-lifting diaphragm gas solenoid valve for civil gas. 2/2-way NC, 1/2"-2", 0-0.4MPa (zero min pressure), VITON seal, brass body, high-speed switching, IP65 coils 22VA/17W & 35VA/30W.
  • IndusKey IK1102 Direct-Lifting Diaphragm Gas Solenoid Valve, 2/2-Way NC, Brass
  • IndusKey IK1102 Direct-Lifting Diaphragm Gas Solenoid Valve, 2/2-Way NC, Brass

Description

1. Product Overview

The IndusKey IK1102 is a normally closed gas solenoid valve employing a direct-lifting diaphragm structure for civil gas service. Designed for high-frequency, high-speed opening and closing, the IK1102 covers port sizes from 1/2" to 2" with a durable brass body and gas-grade VITON sealing, making it ideal for gas distribution, burner control and commercial gas systems.
With an operating pressure range of 0.00–0.4 MPa (no minimum pressure required), media temperatures up to 150°C, and a choice of two IP65-rated coils (S91B: 22 VA AC / 17 W DC; SD01B: 35 VA AC / 30 W DC, both 100% ED), the IK1102 delivers reliable, rapid shutoff across the full range of civil and commercial gas applications. Threaded BSPP/BSPT/NPT and flanged end connections ensure global piping compatibility.

2. Working Principle

The IK1102 employs a direct-lifting diaphragm construction:
  1. Direct actuation — Energizing the solenoid coil lifts the diaphragm assembly directly from its seat, with no pilot stage. The full opening force comes from the solenoid, giving rapid response and the ability to operate from zero pressure.
  2. High-speed switching — The direct-lifting mechanism opens and closes quickly, supporting high cycling frequencies for burner modulation, safety shutoff and automated gas control sequences.
  3. Gas-grade sealing — A VITON diaphragm/seal set matched to civil gas media (natural gas, LPG, town gas) maintains sealing integrity across the −30℃ ~ +150℃ temperature range.
The IK1102 is normally closed (NC) — it opens when energized and closes instantly by spring return when de-energized, providing fail-safe shutoff for gas safety circuits.

3. Key Features & Competitive Advantages

A. High Cycling Frequency

  • Direct-lifting mechanism engineered for repeated, high-frequency operation — ideal for burner ignition sequences and automated process switching.

B. Rapid Switching

  • High-speed open/close action minimizes gas release during shutdown and improves safety response time.

C. Zero Minimum Pressure

  • Operating range 0.00–0.4 MPa with no minimum differential required — works reliably in low-pressure residential and commercial gas lines.

D. Gas-Grade Seal

  • VITON seal material matched to civil gas service for long sealing life and broad gas compatibility.

E. Two Coil Options

  • S91B (22 VA AC / 17 W DC) for orifices 15–25 mm; SD01B (35 VA AC / 30 W DC) for orifices 32–50 mm — optimized power per valve size, both IP65 and 100% ED rated.

F. Full Brass Construction

  • Brass body with stainless-steel internals (armature tube SS304, plunger and stop SS430F, springs SS304, copper shading rings) for durability and corrosion resistance.

G. Flexible Connections

  • BSPP, BSPT, NPT threaded or flange ports, 1/2" through 2" — matching any regional piping standard.

H. Wide Voltage Range

  • DC 12/24V; AC 24/120/240V (60 Hz), 110/220V (50 Hz); ±10% tolerance.

4. Technical Specifications

5. Applications

The IndusKey IK1102 is engineered for reliable gas shutoff and control across civil and commercial installations:
  • Civil Gas Distribution: Residential and commercial gas supply line shutoff and control.
  • Gas Burners: Industrial and commercial burner fuel-gas on/off valves, supporting high-frequency ignition cycles.
  • Gas Supply Lines: Main and branch line shutoff for buildings, plants and gas skid systems.
  • Commercial Cooking Systems: Restaurant and catering kitchen gas safety shutoff.
  • Gas Control Panels: Safety interlock valves integrated into gas train and combustion control panels.
  • Process Gas Switching: Automated on/off control of compatible process gases in industrial equipment.
  • HVAC & Water Heating: Gas-fired boiler, water heater and HVAC unit fuel control.

6. Selection, Ordering & Installation Guidelines

Model Code System

The full valve is configured by a 7-field code — example: IK1102-15GBV S91B1
Note: BSPT threaded and flanged connections are also available — confirm at order.

Selection

  • Function: The IK1102 is normally closed only.
  • Pressure: Full range 0.00–0.4 MPa with no minimum differential — suitable for typical civil gas pressures (verify system pressure stays within range).
  • Coil: S91B standard for orifices up to 25 mm; SD01B required for 32–50 mm (larger flow, higher power).
  • Size: Match orifice/port to required flow using Cv values; check A/B/C/D dimensions for installation clearance.
  • Gas compatibility: VITON seal suits natural gas, LPG and town gas; for special gas media consult IndusKey.

Installation

  • Orientation: Install with the solenoid coil vertically upward where possible; observe the flow-direction arrow on the valve body.
  • Piping: Flush pipelines before commissioning; install a gas-grade filter upstream to protect the diaphragm seat from pipe debris.
  • Safety: As a safety shutoff device, install per local gas regulations; periodic functional testing of the NC shutoff is recommended.
  • Protection: The IP65 coil suits indoor and outdoor installation; protect from direct weather exposure where possible.

Operation & Maintenance

  • Rated for continuous (100% ED) energization.
  • The direct-lifting diaphragm supports high cycling frequency; inspect the diaphragm and seat periodically in high-duty service.