No.UGT-E4-SO2
Electrochemical three-electrode sulfur dioxide gas sensor. 0-10ppm range, 500±100nA/ppm, 0.1ppm resolution, T90<45s. Zero H2S/NH3/NO interference. Φ20.2mm, 2-year life.
  • GASSHIELD UGT-E4-SO2 Sulfur Dioxide Gas Sensor
  • GASSHIELD UGT-E4-SO2 Sulfur Dioxide Gas Sensor
  • GASSHIELD UGT-E4-SO2 Sulfur Dioxide Gas Sensor
  • GASSHIELD UGT-E4-SO2 Sulfur Dioxide Gas Sensor
  • GASSHIELD UGT-E4-SO2 Sulfur Dioxide Gas Sensor
  • GASSHIELD UGT-E4-SO2 Sulfur Dioxide Gas Sensor

Description

1. Product Overview

The GASSHIELD UGT-E4-SO2 is a high-performance fixed-potential electrolytic (electrochemical) sulfur dioxide gas sensor designed for accurate and reliable detection of sulfur dioxide (SO₂) in industrial and environmental applications. Utilizing a three-electrode electrochemical cell architecture, the sensor delivers a detection range of 0–10 ppm with 0.1 ppm resolution and a sensitivity of 500 ± 100 nA/ppm. With T90 < 45 s response time, excellent repeatability (2% of output signal), and long-term stability of <2% signal per month, the UGT-E4-SO2 provides precise SO₂ monitoring for safety-critical environments.
The sensor operates without bias voltage and supports a wide load resistance range of 5–30 Ω, simplifying circuit design integration. Housed in a compact Φ20.2 mm form factor, the UGT-E4-SO2 is ideal for integration into portable gas detectors, fixed gas alarm systems, flue gas monitoring equipment, ambient air quality stations and industrial safety instruments where sulfur dioxide detection and occupational safety are paramount.

2. Technical Principle

The UGT-E4-SO2 employs a fixed-potential electrolytic (electrochemical three-electrode) detection principle. The sensor cell consists of a working electrode, a counter electrode, and a reference electrode immersed in an electrolyte solution separated from the ambient atmosphere by a gas-permeable membrane.
When sulfur dioxide gas diffuses through the membrane and reaches the working electrode, it undergoes an oxidation reaction, releasing electrons and generating a current. Simultaneously, a corresponding reduction reaction occurs at the counter electrode. The magnitude of the current flowing between the working and counter electrodes is directly proportional to the sulfur dioxide concentration in the surrounding atmosphere. This current is converted to a voltage signal via an external load resistor (5–30 Ω) or transimpedance amplifier circuit, enabling precise quantification of SO₂ concentration from 0 to 10 ppm.
The reference electrode maintains a stable potential at the working electrode, ensuring consistent sensitivity and minimizing drift over the sensor's 2-year service life. Zero bias voltage operation reduces power consumption and simplifies interfacing with microcontroller-based acquisition systems.

3. Key Features & Competitive Advantages

A. High Sensitivity & Accuracy

  • High sensitivity of 500 ± 100 nA/ppm with excellent linear response across the 0–10 ppm range.
  • 2-year service life in typical operating conditions with 1-year warranty.

B. Fast Response, Quick Return to Zero

  • T90 < 45 s for rapid detection of sulfur dioxide leaks and hazardous exposure.
  • Quick recovery to baseline after gas exposure, enabling continuous monitoring cycles.

C. Excellent Selectivity

  • No response to H₂S (0 ppm), NH₃ (0 ppm) and NO (0 ppm); minimal response to CO (1 ppm) and H₂ (1 ppm) — accurate SO₂ measurement in mixed-gas industrial environments.

D. Low Power Consumption

  • Zero bias voltage operation minimizes power draw — ideal for battery-powered portable instruments.

E. Excellent Temperature Stability

  • Baseline output remains near zero from −20°C to +30°C; sensitivity varies only from approximately 92% to 115% of the 20°C value across −20°C to +50°C — smooth, well-characterized temperature behavior.

F. Wide Linear Range, Strong Anti-Interference

  • Linear output characteristic simplifies calibration and signal processing.
  • Wide 100 ppm overload capacity protects the sensor from accidental high-concentration exposure.

G. Excellent Repeatability & Stability

  • Repeatability within 2% of output signal for consistent measurement precision.
  • Long-term stability <2% signal per month, reducing frequent recalibration requirements.

H. Compact Size, Cost-Effective

  • Φ20.2 mm compact form factor enables integration into space-constrained instruments.
  • Cost-effective solution for OEM manufacturers developing sulfur dioxide detection products.

4. Technical Specifications

Parameter Specification
Detection Performance
Target Gas Sulfur Dioxide (SO₂)
Detection Principle Electrochemical three-electrode
Detection Range 0 ~ 10 ppm
Max. Overload 100 ppm
Sensitivity 500 ± 100 nA/ppm
Resolution 0.1 ppm
Zero Drift 0 ~ 1 ppm
Linearity Linear
Repeatability 2% of output signal
Long-Term Stability <2% signal / month
Response Time (T90) <45 s
Service Life 2 years
Warranty 1 year
Operating Environment
Operating Temperature −30 ~ +50 °C
Operating Humidity 15 ~ 90% RH (non-condensing)
Operating Pressure 90 ~ 110 kPa
Electrical Characteristics
Bias Voltage 0 mV
Load Resistance 5 ~ 30 Ω
Physical
Dimensions Φ20.2 mm × 16.6 mm, pin Φ1.5 mm
Cross Interference
Carbon Monoxide (CO) @ 500 ppm 1 ppm SO₂ equivalent
Hydrogen Sulfide (H₂S) @ 25 ppm 0 ppm SO₂ equivalent
Ammonia (NH₃) @ 100 ppm 0 ppm SO₂ equivalent
Hydrogen (H₂) @ 1000 ppm 1 ppm SO₂ equivalent
Nitric Oxide (NO) @ 20 ppm 0 ppm SO₂ equivalent
Nitrogen Dioxide (NO₂) @ 20 ppm −24 ppm SO₂ equivalent
Chlorine (Cl₂) @ 20 ppm −5 ppm SO₂ equivalent
Note: Cross-sensitivity may vary by ±30%. Calibration with target gas is recommended. Avoid use in environments with high NO₂ concentrations.

5. Applications

The GASSHIELD UGT-E4-SO2 is engineered for versatile deployment across sulfur dioxide detection and safety monitoring scenarios:
  • Sulfur Dioxide Gas Detectors: Core sensing element for portable and fixed SO₂ detection instruments.
  • Industrial SO₂ Detection: Leak detection in sulfuric acid plants, smelting operations, sulfur recovery units and chemical processing facilities.
  • Flue Gas Monitoring: SO₂ measurement in power plant emissions, industrial boiler flue gas and CEMS (Continuous Emission Monitoring Systems).
  • Ambient Air Quality: Urban air monitoring stations and environmental research applications.
  • Industrial Safety: Fixed and portable gas detection systems for worker protection in SO₂ handling areas.
  • Gas Leak Detection: Early warning systems for sulfur dioxide storage tanks, pipelines and distribution equipment.
  • Biomedical: Sulfur dioxide detection in biomedical research and laboratory applications.
  • Smart Municipal: Municipal air quality and industrial safety monitoring for smart city projects.

6. OEM Integration & Design Guidelines

To maximize design flexibility and ensure optimal sensor performance, the UGT-E4-SO2 is supported by comprehensive integration resources and handling guidelines for equipment manufacturers.
  • Basic Circuit Reference: Standard transimpedance amplifier circuit with R_gain and R_load provided for immediate PCB design integration. Compatible with 5–30 Ω load resistor configurations and zero-bias operation.
  • Temperature Compensation: Baseline output remains near zero from −20°C to +30°C, rising to approximately +2.5 ppm equivalent at +50°C. Sensitivity varies from approximately 92% to 115% of the 20°C value across −20°C to +50°C, following a smooth, monotonic curve. Minimal firmware compensation is required for most applications.
  • Response & Recovery Characterization: Verified response and recovery test data (20 ppm SO₂) enables alarm threshold optimization and adaptive filtering in host firmware.
  • Handling Precautions:
    • Sensor pins must be connected via a PCB socket; soldering or pin bending will damage the sensor.
    • During storage, the working electrode and reference electrode should be kept short-circuited.
    • Avoid contact with organic solvents, alcohol, paints, oils, silicone adhesives, and high-concentration gases.
    • Calibrate and test with standard gas using air as the background gas; oxygen participation is required for the electrochemical reaction.
    • Avoid prolonged use in corrosive gas environments.
    • Non-standard testing methods (concentrated ammonia water, cigarette smoke, lighter gas, exhaled breath, alcohol vapors) will expose the sensor to damaging concentrations — always use target gas with air as the background.
  • Calibration Recommendation: Calibration with the target gas is recommended; cross-sensitivity may vary by ±30%. Calibration should be performed in clean atmosphere with stable, gentle gas flow to simulate a diffusion state.