1. Product Overview
The GASSHIELD UGT-E4-O3 is a high-performance fixed-potential electrolytic (electrochemical) ozone gas sensor designed for accurate and reliable detection of ozone (O₃) in industrial, medical and environmental applications. Utilizing a three-electrode electrochemical cell architecture, the sensor delivers a detection range of 0–5 ppm with 0.1 ppm resolution and a sensitivity of −700 ± 250 nA/ppm. With T90 < 60 s response time, excellent repeatability (2% of output signal), and long-term stability of <2% signal per month, the UGT-E4-O3 provides precise O₃ monitoring for safety-critical environments.
The sensor operates without bias voltage and supports a recommended load resistance range of 5–30 Ω, simplifying circuit design integration. Housed in a compact Φ20.2 mm form factor, the UGT-E4-O3 is ideal for integration into portable gas detectors, fixed gas alarm systems, ozone generators and monitors, water treatment equipment, medical ozone devices and air purification systems where ozone leak detection and concentration control are paramount.
2. Technical Principle
The UGT-E4-O3 employs a fixed-potential electrolytic (electrochemical three-electrode) detection principle. The sensor cell consists of a working electrode, a counter electrode, and a reference electrode immersed in an electrolyte solution separated from the ambient atmosphere by a gas-permeable membrane. Through electronic circuitry, the working electrode and the reference electrode are held at an appropriate potential, at which the electrochemical reduction of ozone occurs on the working electrode.
When ozone gas diffuses through the membrane and reaches the working electrode, it undergoes a reduction reaction, releasing electrons and generating a current. Simultaneously, a corresponding oxidation reaction occurs at the counter electrode. The magnitude of the current flowing between the working and counter electrodes is directly proportional to the ozone concentration in the surrounding atmosphere. This current is converted to a voltage signal via an external load resistor (5–30 Ω) or transimpedance amplifier circuit, enabling precise quantification of O₃ concentration from 0 to 5 ppm.
The reference electrode maintains a stable potential at the working electrode, ensuring consistent sensitivity and minimizing drift over the sensor's 2-year service life. Zero bias voltage operation reduces power consumption and simplifies interfacing with microcontroller-based acquisition systems.
3. Key Features & Competitive Advantages
A. Excellent Baseline Temperature Stability
B. Excellent Selectivity
-
No response to CO (0 ppm), SO₂ (0 ppm), H₂ (0 ppm), NH₃ (0 ppm) and NO (0 ppm) — accurate ozone measurement in mixed-gas environments.
C. High Accuracy & Long Service Life
D. Fast Response, Quick Return to Zero
-
T90 < 60 s for rapid detection of ozone leaks and exposure events.
-
Quick recovery to baseline after gas exposure, enabling continuous monitoring cycles.
E. Low Power Consumption, High Sensitivity
F. Wide Linear Range, Strong Anti-Interference
G. Excellent Repeatability & Stability
-
Repeatability within 2% of output signal for consistent measurement precision.
-
Long-term stability <2% signal per month, reducing frequent recalibration requirements.
H. Compact Size, Cost-Effective
4. Technical Specifications
Note: Cross-sensitivity may vary by ±30%. Calibration with target gas is recommended. Avoid use in environments with high NO₂ or Cl₂ concentrations.
5. Applications
The GASSHIELD UGT-E4-O3 is engineered for versatile deployment across ozone detection and safety monitoring scenarios:
-
Ozone Gas Detectors: Core sensing element for portable and fixed O₃ detection instruments.
-
Industrial Ozone Detection: Leak detection in ozone generation systems, semiconductor cleaning and industrial oxidation processes.
-
Water Treatment: Ozone concentration monitoring in drinking water disinfection, wastewater treatment and swimming pool ozonation systems.
-
Medical Ozone Devices: Concentration control and leak detection in medical ozone therapy and sterilization equipment.
-
Air Purification: Ozone level monitoring in air purifiers, sterilization equipment and deodorization systems.
-
Biomedical: Ozone detection in biomedical research and laboratory applications.
-
Food & Beverage: Ozone monitoring in food sterilization and cold storage preservation systems.
-
Smart Municipal: Municipal water treatment and air quality ozone monitoring for smart city projects.
6. OEM Integration & Design Guidelines
To maximize design flexibility and ensure optimal sensor performance, the UGT-E4-O3 is supported by comprehensive integration resources and handling guidelines for equipment manufacturers.
-
Basic Circuit Reference: Standard transimpedance amplifier circuit with R_gain and R_load provided for immediate PCB design integration. Compatible with 5–30 Ω recommended load resistor configurations and zero-bias operation.
-
Temperature Compensation: Baseline output remains within approximately ±0.4 ppm equivalent across the full −30°C to +50°C range — among the best zero-stability profiles in the E4 series. Sensitivity varies from approximately 85% to 116% of the 20°C value across the same range, following a smooth, well-characterized curve. Minimal firmware compensation is required for most applications.
-
Response & Recovery Characterization: Verified response and recovery test data (5 ppm O₃) enables alarm threshold optimization and adaptive filtering in host firmware.
-
Handling Precautions:
-
Sensor pins must be connected via a PCB socket; soldering or pin bending will damage the sensor.
-
During storage, the working electrode and reference electrode should be kept short-circuited.
-
Avoid contact with organic solvents, alcohol, paints, oils, silicone adhesives, and high-concentration gases.
-
Calibrate and test with standard gas using air as the background gas; oxygen participation is required for the electrochemical reaction.
-
Avoid prolonged use in corrosive gas environments.
-
Non-standard testing methods (concentrated ammonia water, cigarette smoke, lighter gas, exhaled breath, alcohol vapors) will expose the sensor to damaging concentrations — always use target gas with air as the background.
-
Calibration Recommendation: Calibration with the target gas is recommended; cross-sensitivity may vary by ±30%. Calibration should be performed in clean atmosphere with stable, gentle gas flow to simulate a diffusion state.