GASSHIELD UGT-E4-NO2 Nitrogen Dioxide Gas Sensor

No.UGT-E4-NO2
Electrochemical three-electrode nitrogen dioxide gas sensor. 0-20ppm range, −500±150nA/ppm, 0.5ppm resolution, T90<30s. Zero CO/NO interference. Φ20.2mm, 2-year life.
  • GASSHIELD UGT-E4-NO2 Nitrogen Dioxide Gas Sensor
  • GASSHIELD UGT-E4-NO2 Nitrogen Dioxide Gas Sensor
  • GASSHIELD UGT-E4-NO2 Nitrogen Dioxide Gas Sensor
  • GASSHIELD UGT-E4-NO2 Nitrogen Dioxide Gas Sensor
  • GASSHIELD UGT-E4-NO2 Nitrogen Dioxide Gas Sensor
  • GASSHIELD UGT-E4-NO2 Nitrogen Dioxide Gas Sensor

Description

1. Product Overview

The GASSHIELD UGT-E4-NO2 is a high-performance fixed-potential electrolytic (electrochemical) nitrogen dioxide gas sensor designed for accurate and reliable detection of nitrogen dioxide (NO₂) in industrial, automotive and environmental applications. Utilizing a three-electrode electrochemical cell architecture, the sensor delivers a detection range of 0–20 ppm with 0.5 ppm resolution and a sensitivity of −500 ± 150 nA/ppm. With rapid T90 < 30 s response time, excellent repeatability (2% of output signal), and long-term stability of <2% signal per month, the UGT-E4-NO2 provides precise NO₂ monitoring for safety-critical environments.
The sensor operates without bias voltage and supports a wide load resistance range of 5–30 Ω, simplifying circuit design integration. Housed in a compact Φ20.2 mm form factor, the UGT-E4-NO2 is ideal for integration into portable gas detectors, fixed gas alarm systems, air quality monitoring stations, vehicle emission testing equipment and industrial safety instruments where nitrogen dioxide detection and occupational safety are paramount.

2. Technical Principle

The UGT-E4-NO2 employs a fixed-potential electrolytic (electrochemical three-electrode) detection principle. The sensor cell consists of a working electrode, a counter electrode, and a reference electrode immersed in an electrolyte solution separated from the ambient atmosphere by a gas-permeable membrane.
When nitrogen dioxide gas diffuses through the membrane and reaches the working electrode, it undergoes a reduction reaction, releasing electrons and generating a current. Simultaneously, a corresponding oxidation reaction occurs at the counter electrode. The magnitude of the current flowing between the working and counter electrodes is directly proportional to the nitrogen dioxide concentration in the surrounding atmosphere. This current is converted to a voltage signal via an external load resistor (5–30 Ω) or transimpedance amplifier circuit, enabling precise quantification of NO₂ concentration from 0 to 20 ppm.
The reference electrode maintains a stable potential at the working electrode, ensuring consistent sensitivity and minimizing drift over the sensor's 2-year service life. Zero bias voltage operation reduces power consumption and simplifies interfacing with microcontroller-based acquisition systems.

3. Key Features & Competitive Advantages

A. Rapid Response

  • T90 < 30 s — among the fastest in the E4 electrochemical series — for immediate detection of NO₂ exposure.

B. Excellent Selectivity

  • Virtually no response to CO (0 ppm), SO₂ (0 ppm), NO (0 ppm) and Ethylene (0 ppm) — ideal for diesel/vehicle environments where NO co-exists.

C. High Accuracy & Long Service Life

  • Detection accuracy with excellent linear response across the 0–20 ppm range.
  • 2-year service life in typical operating conditions with 1-year warranty.

D. Fast Recovery, Stable Baseline

  • Quick return to zero after gas exposure, enabling continuous monitoring cycles.
  • Baseline temperature drift within ±0.1 ppm equivalent across −20°C to +50°C — excellent zero stability.

E. Low Power Consumption

  • Zero bias voltage operation minimizes power draw — ideal for battery-powered portable instruments and wireless air quality nodes.

F. Excellent Repeatability & Stability

  • Repeatability within 2% of output signal for consistent measurement precision.
  • Long-term stability <2% signal per month, reducing frequent recalibration requirements.

G. Wide Range of Application Fields

  • Suitable for industrial safety, air quality monitoring, vehicle emission testing, tunnels and environmental monitoring.

H. Compact Size, Cost-Effective

  • Φ20.2 mm compact form factor enables integration into space-constrained instruments.
  • Cost-effective solution for OEM manufacturers developing nitrogen dioxide detection products.

4. Technical Specifications

Parameter Specification
Detection Performance
Target Gas Nitrogen Dioxide (NO₂)
Detection Principle Electrochemical three-electrode
Detection Range 0 ~ 20 ppm
Max. Overload 50 ppm
Sensitivity −500 ± 150 nA/ppm
Resolution 0.5 ppm
Zero Drift 0 ~ 1 ppm
Linearity Linear
Repeatability 2% of output signal
Long-Term Stability <2% signal / month
Response Time (T90) <30 s
Service Life 2 years
Warranty 1 year
Operating Environment
Operating Temperature −30 ~ +50 °C
Operating Humidity 15 ~ 90% RH (non-condensing)
Operating Pressure 90 ~ 110 kPa
Electrical Characteristics
Bias Voltage 0 mV
Load Resistance 5 ~ 30 Ω
Physical
Dimensions Φ20.2 mm × 16.6 mm, pin Φ1.5 mm
Cross Interference
Carbon Monoxide (CO) @ 300 ppm 0 ppm NO₂ equivalent
Sulfur Dioxide (SO₂) @ 20 ppm 0 ppm NO₂ equivalent
Hydrogen Sulfide (H₂S) @ 25 ppm −1 ppm NO₂ equivalent
Chlorine (Cl₂) @ 50 ppm 6 ppm NO₂ equivalent
Nitric Oxide (NO) @ 20 ppm 0 ppm NO₂ equivalent
Ethylene (C₂H₄) @ 50 ppm 0 ppm NO₂ equivalent
Note: Cross-sensitivity may vary by ±30%. Calibration with target gas is recommended.

5. Applications

The GASSHIELD UGT-E4-NO2 is engineered for versatile deployment across nitrogen dioxide detection and safety monitoring scenarios:
  • Nitrogen Dioxide Gas Detectors: Core sensing element for portable and fixed NO₂ detection instruments.
  • Industrial NO₂ Detection: Leak detection in nitric acid plants, chemical synthesis and industrial processes.
  • Air Quality Monitoring: Urban ambient air monitoring stations and roadside air quality sensors.
  • Vehicle Emission Testing: NO₂ measurement in diesel vehicle emission inspection and tunnel monitoring.
  • Tunnels & Underground: Nitrogen dioxide monitoring in road tunnels, parking garages and underground facilities.
  • Industrial Safety: Fixed and portable gas detection systems for worker protection in NO₂ handling areas.
  • Biomedical: Nitrogen dioxide detection in biomedical research and laboratory applications.
  • Smart Municipal: Municipal air quality monitoring networks for smart city projects.

6. OEM Integration & Design Guidelines

To maximize design flexibility and ensure optimal sensor performance, the UGT-E4-NO2 is supported by comprehensive integration resources and handling guidelines for equipment manufacturers.
  • Basic Circuit Reference: Standard transimpedance amplifier circuit with R_gain and R_load provided for immediate PCB design integration. Compatible with 5–30 Ω load resistor configurations and zero-bias operation.
  • Temperature Compensation: Baseline output remains within approximately ±0.1 ppm equivalent across −20°C to +50°C — excellent zero stability. Sensitivity varies from approximately 88% to 110% of the 20°C value across the same range, among the most temperature-stable profiles in the E4 series. Minimal firmware compensation is required.
  • Response & Recovery Characterization: Verified response and recovery test data (10 ppm NO₂) enables alarm threshold optimization and adaptive filtering in host firmware.
  • Handling Precautions:
    • Sensor pins must be connected via a PCB socket; soldering or pin bending will damage the sensor.
    • During storage, the working electrode and reference electrode should be kept short-circuited.
    • Avoid contact with organic solvents, alcohol, paints, oils, silicone adhesives, and high-concentration gases.
    • Calibrate and test with standard gas using air as the background gas; oxygen participation is required for the electrochemical reaction.
    • Avoid prolonged use in corrosive gas environments.
    • Non-standard testing methods (concentrated ammonia water, cigarette smoke, lighter gas, exhaled breath, alcohol vapors) will expose the sensor to damaging concentrations — always use target gas with air as the background.
  • Calibration Recommendation: Calibration with the target gas is recommended; cross-sensitivity may vary by ±30%. Calibration should be performed in clean atmosphere with stable, gentle gas flow to simulate a diffusion state.