• GASSHIELD UGT-E4-NH3 Ammonia Gas Sensor (0-100ppm)
  • GASSHIELD UGT-E4-NH3 Ammonia Gas Sensor (0-100ppm)
  • GASSHIELD UGT-E4-NH3 Ammonia Gas Sensor (0-100ppm)
  • GASSHIELD UGT-E4-NH3 Ammonia Gas Sensor (0-100ppm)
  • GASSHIELD UGT-E4-NH3 Ammonia Gas Sensor (0-100ppm)
  • GASSHIELD UGT-E4-NH3 Ammonia Gas Sensor (0-100ppm)
  • GASSHIELD UGT-E4-NH3 Ammonia Gas Sensor (0-100ppm)
  • GASSHIELD UGT-E4-NH3 Ammonia Gas Sensor (0-100ppm)
  • GASSHIELD UGT-E4-NH3 Ammonia Gas Sensor (0-100ppm)
  • GASSHIELD UGT-E4-NH3 Ammonia Gas Sensor (0-100ppm)
  • GASSHIELD UGT-E4-NH3 Ammonia Gas Sensor (0-100ppm)
  • GASSHIELD UGT-E4-NH3 Ammonia Gas Sensor (0-100ppm)

GASSHIELD UGT-E4-NH3 Ammonia Gas Sensor (0-100ppm)

No.UGT-E4-NH3
Electrochemical three-electrode ammonia gas sensor. 0-100ppm range, 160±40nA/ppm, 1ppm resolution, T90<90s. Φ20.2mm, zero bias, 2-year life.
  • GASSHIELD UGT-E4-NH3 Ammonia Gas Sensor (0-100ppm)
  • GASSHIELD UGT-E4-NH3 Ammonia Gas Sensor (0-100ppm)
  • GASSHIELD UGT-E4-NH3 Ammonia Gas Sensor (0-100ppm)
  • GASSHIELD UGT-E4-NH3 Ammonia Gas Sensor (0-100ppm)
  • GASSHIELD UGT-E4-NH3 Ammonia Gas Sensor (0-100ppm)
  • GASSHIELD UGT-E4-NH3 Ammonia Gas Sensor (0-100ppm)

Description

1. Product Overview

The GASSHIELD UGT-E4-NH3 is a high-performance fixed-potential electrolytic (electrochemical) ammonia gas sensor designed for accurate and reliable detection of ammonia (NH₃) in industrial, agricultural and environmental applications. Utilizing a three-electrode electrochemical cell architecture, the sensor delivers a detection range of 0–100 ppm with 1 ppm resolution and a sensitivity of 160 ± 40 nA/ppm. With T90 < 90 s response time, excellent repeatability (2% of output signal), and long-term stability of <2% signal per month, the UGT-E4-NH3 provides precise NH₃ monitoring for safety-critical environments.
The sensor operates without bias voltage and supports a wide load resistance range of 5–30 Ω, simplifying circuit design integration. Housed in a compact Φ20.2 mm form factor, the UGT-E4-NH3 is ideal for integration into portable gas detectors, fixed gas alarm systems, livestock farming monitoring equipment, refrigeration facility detectors and industrial safety instruments where ammonia leak detection and occupational safety are paramount.

2. Technical Principle

The UGT-E4-NH3 employs a fixed-potential electrolytic (electrochemical three-electrode) detection principle. The sensor cell consists of a working electrode, a counter electrode, and a reference electrode immersed in an electrolyte solution separated from the ambient atmosphere by a gas-permeable membrane.
When ammonia gas diffuses through the membrane and reaches the working electrode, it undergoes an oxidation reaction, releasing electrons and generating a current. Simultaneously, a corresponding reduction reaction occurs at the counter electrode. The magnitude of the current flowing between the working and counter electrodes is directly proportional to the ammonia concentration in the surrounding atmosphere. This current is converted to a voltage signal via an external load resistor (5–30 Ω) or transimpedance amplifier circuit, enabling precise quantification of NH₃ concentration from 0 to 100 ppm.
The reference electrode maintains a stable potential at the working electrode, ensuring consistent sensitivity and minimizing drift over the sensor's 2-year service life. Zero bias voltage operation reduces power consumption and simplifies interfacing with microcontroller-based acquisition systems.

3. Key Features & Competitive Advantages

A. High Accuracy & Long Service Life

  • Detection accuracy with excellent linear response across the 0–100 ppm range.
  • 2-year service life in typical operating conditions with 1-year warranty.

B. Fast Response, Quick Return to Zero

  • T90 < 90 s for rapid detection of ammonia leaks and hazardous exposure.
  • Quick recovery to baseline after gas exposure, enabling continuous monitoring cycles.

C. Low Power Consumption, High Sensitivity

  • Zero bias voltage operation minimizes power draw — ideal for battery-powered portable instruments.
  • High sensitivity of 160 ± 40 nA/ppm ensures reliable detection across the full measurement range.

D. Wide Linear Range, Strong Anti-Interference

  • Linear output characteristic simplifies calibration and signal processing.
  • No response to common gases: CO (0 ppm), H₂ (0 ppm), Isobutylene (0 ppm).

E. Excellent Repeatability & Stability

  • Repeatability within 2% of output signal for consistent measurement precision.
  • Long-term stability <2% signal per month, reducing frequent recalibration requirements.

F. Wide Range of Application Fields

  • Suitable for livestock farming, refrigeration, chemical processing, industrial safety, and environmental monitoring.

G. Compact Size, Cost-Effective

  • Φ20.2 mm compact form factor enables integration into space-constrained instruments.
  • Cost-effective solution for OEM manufacturers developing ammonia detection products.

4. Technical Specifications

Parameter Specification
Detection Performance
Target Gas Ammonia (NH₃)
Detection Principle Electrochemical three-electrode
Detection Range 0 ~ 100 ppm
Max. Overload 200 ppm
Sensitivity 160 ± 40 nA/ppm
Resolution 1 ppm
Zero Drift 0 ~ 1 ppm
Linearity Linear
Repeatability 2% of output signal
Long-Term Stability <2% signal / month
Response Time (T90) <90 s
Service Life 2 years
Warranty 1 year
Operating Environment
Operating Temperature −30 ~ +50 °C
Operating Humidity 15 ~ 90% RH (non-condensing)
Operating Pressure 90 ~ 110 kPa
Electrical Characteristics
Bias Voltage 0 mV
Load Resistance 5 ~ 30 Ω
Physical
Dimensions Φ20.2 mm × 16.6 mm, pin Φ1.5 mm
Cross Interference
Carbon Monoxide (CO) @ 50 ppm 0 ppm NH₃ equivalent
Carbon Dioxide (CO₂) @ 100 ppm 25 ppm NH₃ equivalent 
Hydrogen (H₂) @ 1000 ppm 0 ppm NH₃ equivalent
Isobutylene (C₄H₈) @ 100 ppm 0 ppm NH₃ equivalent
Note: Cross-sensitivity may vary by ±30%. Calibration with target gas is recommended.  The CO₂ interference value requires verification against the original datasheet.

5. Applications

The GASSHIELD UGT-E4-NH3 is engineered for versatile deployment across ammonia detection and safety monitoring scenarios:
  • Ammonia Gas Alarms: Core sensing element for residential and commercial ammonia leak alarm systems.
  • Livestock Farming: Ammonia monitoring in poultry houses, pig farms and livestock facilities for animal health and worker safety.
  • Refrigeration Facilities: NH₃ leak detection in cold storage warehouses and industrial refrigeration systems using ammonia as refrigerant.
  • Industrial On-Site Detection: Ammonia monitoring in chemical plants, fertilizer production and synthesis processes.
  • Gas Leak Detection: Early warning systems for ammonia storage tanks, pipelines and distribution equipment.
  • Atmospheric Monitoring: Ambient ammonia monitoring stations and environmental research applications.
  • Smart Municipal: Municipal environmental ammonia monitoring for smart city projects.
  • Wastewater Treatment: Ammonia detection in sewage and waste treatment facilities.

6. OEM Integration & Design Guidelines

To maximize design flexibility and ensure optimal sensor performance, the UGT-E4-NH3 is supported by comprehensive integration resources and handling guidelines for equipment manufacturers.
  • Basic Circuit Reference: Standard transimpedance amplifier circuit with R_gain and R_load provided for immediate PCB design integration. Compatible with 5–30 Ω load resistor configurations and zero-bias operation.
  • Temperature Compensation: Baseline output remains near zero from −30°C to +30°C, rising to approximately +4 ppm equivalent at +50°C. Sensitivity remains within approximately 0.75–1.05 of the 20°C value across −20°C to +50°C — excellent temperature stability for this sensor class. Firmware temperature compensation is recommended for high-temperature applications.
  • Response & Recovery Characterization: Verified response and recovery test data (50 ppm NH₃) enables alarm threshold optimization and adaptive filtering in host firmware.
  • Handling Precautions:
    • Sensor pins must be connected via a PCB socket; soldering or pin bending will damage the sensor.
    • During storage, the working electrode and reference electrode should be kept short-circuited.
    • Avoid contact with organic solvents, alcohol, paints, oils, silicone adhesives, and high-concentration gases.
    • Calibrate and test with standard gas using air as the background gas; oxygen participation is required for the electrochemical reaction.
    • Avoid prolonged use in corrosive gas environments.
    • Non-standard testing methods (concentrated ammonia water, cigarette smoke, lighter gas, exhaled breath, alcohol vapors) will expose the sensor to damaging concentrations — always use target gas with air as the background.
  • Calibration Recommendation: Calibration with the target gas is recommended; cross-sensitivity may vary by ±30%. Calibration should be performed in clean atmosphere with stable, gentle gas flow to simulate a diffusion state.

Download