1. Product Overview
The GASSHIELD UGT-E4-HCHO is a high-performance fixed-potential electrolytic (electrochemical) formaldehyde gas sensor designed for accurate and reliable detection of formaldehyde (HCHO) in industrial and environmental applications. Utilizing a three-electrode electrochemical cell architecture, the sensor delivers a detection range of 0–200 ppm with 1 ppm resolution and a sensitivity of 350 ± 150 nA/ppm at 20°C. With T90 ≤ 110 s response time, excellent repeatability (2% of output signal), and long-term stability of <±2% signal per month, the UGT-E4-HCHO provides precise formaldehyde monitoring for high-concentration industrial and safety-critical environments.
The sensor operates without bias voltage and supports a wide load resistance range of 5–30 Ω, simplifying circuit design integration. Housed in a compact Φ20.2 mm form factor, the UGT-E4-HCHO is ideal for integration into industrial formaldehyde monitors, fixed gas detection systems, chemical process control instruments and occupational safety equipment.
2. Technical Principle
The UGT-E4-HCHO employs a fixed-potential electrolytic (electrochemical three-electrode) detection principle. The sensor cell consists of a working electrode, a counter electrode, and a reference electrode immersed in an electrolyte solution separated from the ambient atmosphere by a gas-permeable membrane.
When formaldehyde gas diffuses through the membrane and reaches the working electrode, it undergoes an oxidation reaction, releasing electrons and generating a current. Simultaneously, a corresponding reduction reaction occurs at the counter electrode. The magnitude of the current flowing between the working and counter electrodes is directly proportional to the formaldehyde concentration in the surrounding atmosphere. This current is converted to a voltage signal via an external load resistor (5–30 Ω) or transimpedance amplifier circuit, enabling precise quantification of HCHO concentration from 0 to 200 ppm.
The reference electrode maintains a stable potential at the working electrode, ensuring consistent sensitivity and minimizing drift over the sensor's 2-year service life. Zero bias voltage operation reduces power consumption and simplifies interfacing with microcontroller-based acquisition systems.
3. Key Features & Competitive Advantages
A. High Accuracy & Long Service Life
B. Fast Response, Quick Return to Zero
-
T90 ≤ 110 s for detection of formaldehyde leaks and hazardous exposure.
-
Quick recovery to baseline after gas exposure, enabling continuous monitoring cycles.
C. Low Power Consumption, High Sensitivity
D. Wide Linear Range, Strong Anti-Interference
-
Linear output characteristic simplifies calibration and signal processing.
-
Minimal response to common gases: CO₂ (0 ppm), NH₃ (0 ppm), H₂ (1.5 ppm).
E. Excellent Repeatability & Stability
-
Repeatability within 2% of output signal for consistent measurement precision.
-
Long-term stability <±2% signal per month, reducing frequent recalibration requirements.
F. Wide Range of Application Fields
-
Suitable for industrial safety, chemical processing, air purification, and environmental monitoring.
G. Compact Size, Cost-Effective
4. Technical Specifications
Note: Cross-sensitivity may vary by ±30%. Calibration with target gas is recommended.
5. Applications
The GASSHIELD UGT-E4-HCHO is engineered for versatile deployment across formaldehyde detection and safety monitoring scenarios:
-
Industrial Process Monitoring: Formaldehyde concentration measurement in resin manufacturing, chemical synthesis and wood processing plants.
-
Industrial Safety: Fixed and portable gas detection systems for worker protection in formaldehyde handling areas.
-
Gas Leak Detection: Early warning systems for formaldehyde storage tanks, pipelines and production equipment.
-
Steel and Chemical Industry: Safety monitoring in facilities using formaldehyde-based processes.
-
Air Purification: Monitoring high-concentration formaldehyde in industrial air treatment systems.
-
Instrumentation: Core sensing element for industrial formaldehyde analyzers and detection instruments.
-
Environmental Monitoring: Ambient and emission formaldehyde monitoring in industrial zones.
-
Laboratory & Research: Formaldehyde detection in research and testing institutions.
6. OEM Integration & Design Guidelines
To maximize design flexibility and ensure optimal sensor performance, the UGT-E4-HCHO is supported by comprehensive integration resources and handling guidelines for equipment manufacturers.
-
Basic Circuit Reference: Standard transimpedance amplifier circuit with R_gain and R_load provided for immediate PCB design integration. Compatible with 5–30 Ω load resistor configurations and zero-bias operation.
-
Temperature Compensation: Zero drift is specified at ±1 ppm across −20°C to +50°C; however, baseline output rises noticeably above 40°C (approximately +5 ppm equivalent at 50°C) and sensitivity increases to approximately 140% of the 20°C value at 50°C. Firmware temperature compensation is recommended for applications operating outside the 0–30°C range.
-
Response & Recovery Characterization: Verified response and recovery test data (10 ppm HCHO) enables alarm threshold optimization and adaptive filtering in host firmware.
-
Handling Precautions:
-
Sensor pins must be connected via a PCB socket; soldering or pin bending will damage the sensor.
-
During storage, the working electrode and reference electrode should be kept short-circuited.
-
Avoid contact with organic solvents, alcohol, paints, oils, silicone adhesives, and high-concentration gases.
-
Calibrate and test with standard gas using air as the background gas; oxygen participation is required for the electrochemical reaction.
-
Avoid prolonged use in corrosive gas environments.
-
Non-standard testing methods (concentrated ammonia water, cigarette smoke, lighter gas, exhaled breath, alcohol vapors) will expose the sensor to damaging concentrations — always use target gas with air as the background.
-
Calibration Recommendation: Calibration with the target gas is recommended; cross-sensitivity may vary by ±30%. Calibration should be performed in clean atmosphere with stable, gentle gas flow to simulate a diffusion state.