GASSHIELD UGT-C5H Hydrogen Gas Sensor

No.UGT-C5H
Catalytic combustion hydrogen gas sensor. 0-100%LEL, ≥16mV/20%LEL, T90<10s, 5-year life. Φ12×8mm, DC 2.5V, excellent poisoning resistance.
  • GASSHIELD UGT-C5H Hydrogen Gas Sensor
  • GASSHIELD UGT-C5H Hydrogen Gas Sensor
  • GASSHIELD UGT-C5H Hydrogen Gas Sensor
  • GASSHIELD UGT-C5H Hydrogen Gas Sensor
  • GASSHIELD UGT-C5H Hydrogen Gas Sensor
  • GASSHIELD UGT-C5H Hydrogen Gas Sensor
  • GASSHIELD UGT-C5H Hydrogen Gas Sensor
  • GASSHIELD UGT-C5H Hydrogen Gas Sensor

Description

1. Product Overview

The GASSHIELD UGT-C5H is a high-performance catalytic combustion-type hydrogen gas sensor designed for accurate and reliable detection of Hydrogen (H₂) in industrial and environmental applications. With a detection range of 0–100% LEL, output sensitivity of ≥16 mV at 20% LEL hydrogen, and rapid T90 < 10 s response time, the UGT-C5H delivers fast, precise hydrogen detection for safety-critical applications.
The sensor operates on the proven catalytic combustion principle with a Wheatstone bridge circuit, providing superior linearity (±3%), excellent repeatability and 5-year operating life in clean air. With strong vibration resistance, excellent poisoning resistance and stable output across −40°C to +70°C, the compact Φ12 mm UGT-C5H is ideal for integration into portable gas detectors, fixed gas alarm controllers, hydrogen energy systems and industrial gas detection instruments.

2. Technical Principle

The UGT-C5H employs a catalytic combustion (pellistor) detection principle. The sensor consists of a matched pair of elements — a catalytic (detection) element and a reference (compensation) element — arranged in a Wheatstone bridge circuit.
When hydrogen gas diffuses into the sensor and contacts the catalytic element, it oxidizes on the heated catalyst surface, causing a rise in element temperature and resistance. The reference element, coated with inert material, remains unaffected by the gas, compensating for ambient temperature and humidity variations. The resulting resistance imbalance in the bridge generates a voltage output proportional to the gas concentration, delivering a linear response from 0 to 100% LEL.
The sensor exhibits excellent directional stability with minimal output change regardless of installation orientation (360° vertical rotation test).

3. Key Features & Competitive Advantages

A. Hydrogen-Specific Optimization

  • Dedicated catalytic element formulation optimized for hydrogen (H₂) detection.
  • High sensitivity of ≥16 mV at 20% LEL hydrogen with superior linearity (±3%, 60% LEL calibrated).

B. Fast Response & Recovery

  • T90 < 10 s at 50% LEL for rapid leak detection.
  • Recovery time of only 15 s, enabling continuous monitoring cycles.

C. Good Long-Term Working Stability

  • 5-year operating life in clean air with minimal output drift.
  • 2-year warranty from date of shipment.

D. Excellent Poisoning Resistance

  • Outstanding resistance to silicon poisoning (HMDS), maintaining stable output even at 400 ppm HMDS exposure.

E. Strong Vibration Resistance

  • Robust construction withstands mechanical vibration in industrial and vehicle-mounted applications.

F. Excellent Repeatability

  • Consistent output signal with tight batch-to-batch uniformity — over 60% of units fall within the 21–28 mV window.

G. Wide Operating Environment

  • Operating temperature: −40°C to +70°C.
  • Continuous humidity: 15–90% RH (non-condensing); intermittent: 0–99% RH.
  • Low power consumption: <600 mW.

H. Compact Size, Cost-Effective

  • Φ12 mm compact form factor for space-constrained instrument designs.
  • Cost-effective solution for OEM manufacturers.

4. Technical Specifications

Parameter Specification
Detection Performance
Target Gas Hydrogen (H₂)
Detection Principle Catalytic combustion
Detection Range 0 ~ 100% LEL
Detection Accuracy ±3% LEL
Zero Drift ±2% LEL
Full-Scale Deviation ±5% FS
Linearity ±3% (0–100% LEL, 60% LEL calibrated)
Response Time T90 < 10 s (50% LEL)
Recovery Time 15 s
Sensitivity Output ≥16 mV / 20% LEL Hydrogen
Zero Output ±25 mV
Operating Life 5 years (in clean air)
Warranty 2 years (from date of shipment)
Electrical Characteristics
Operating Voltage DC 2.5 ± 0.1 V
Operating Current (at 2.5V) 170 ~ 190 mA
Power Consumption < 600 mW
Detection Circuit Wheatstone bridge (Vin+/Vin−, Vout+/Vout−)
Operating Environment
Operating Temperature −40 ~ +70 °C
Operating Humidity 15–90% RH continuous, 0–99% RH intermittent (non-condensing)
Storage Environment
Storage Temperature −20 ~ +50 °C
Storage Humidity ≤95% RH (non-condensing)
Physical
Dimensions Φ12 mm × 13 mm (8 mm + 5 mm), pin Φ0.75 mm
Relative Sensitivity to Common Gases (%): Hydrogen 100 | Ammonia 136 | Methane 139 | Ethylene 104 | Ethane 83 | Propane 85 | Isobutane 76 | Butane 61 | Isobutylene 61 | Isobutanol 56 | Hexane 58 | Diethyl ether 46
Note: Relative sensitivity values may vary with production batch and test environment. Calibrate with the target gas before use. Example: calibrating a hydrogen detector with 50% LEL methane standard gas yields a reading of 50 × (139÷100) = 69.5% LEL.

5. Applications

The GASSHIELD UGT-C5H is engineered for versatile deployment across hydrogen detection and safety monitoring scenarios:
  • Hydrogen Energy: H₂ leak detection in hydrogen fueling stations, fuel cell systems and hydrogen production facilities.
  • Industrial Safety: Fixed and portable gas detection systems for chemical processing, semiconductor manufacturing and industrial facilities using hydrogen.
  • Gas Leak Detection: Early warning systems for hydrogen pipelines, storage tanks, distribution equipment and battery rooms.
  • Laboratory & Research: Gas detection in laboratories and research institutions using hydrogen as a carrier or process gas.
  • Battery Rooms & UPS Facilities: Hydrogen monitoring in lead-acid battery charging rooms and telecom facilities.
  • Mining & Tunnels: Combustible gas monitoring in underground operations and confined spaces.

6. OEM Integration & Design Guidelines

To maximize design flexibility and ensure optimal sensor performance, the UGT-C5H is supported by comprehensive integration resources and handling guidelines for equipment manufacturers.
  • Basic Circuit Reference: Standard Wheatstone bridge circuit (Vin+/Vin− power input, Vout+/Vout− differential output) with recommended reference detection circuit provided for immediate PCB design integration. Operating voltage: DC 2.5 ± 0.1 V.
  • Temperature Compensation: See Section 5.2 for the temperature response curve (−40°C to +70°C, zero-compensated) to guide firmware compensation algorithms.
  • Humidity Compensation: See Section 5.3 for humidity response data (20–95% RH) for environmental robustness design.
  • Response & Recovery Characterization: See Sections 5.1 and 5.6 for gas response and long-term drift data to optimize alarm thresholds and calibration intervals.
  • Gas-Specific Calibration: Use the Relative Sensitivity Table (Section 4) to convert readings between calibration gas and target gas: Detector reading = calibration gas concentration × (calibration gas coefficient ÷ target gas coefficient). Calibrate with the target gas before use; cross-sensitive gas calibration cannot guarantee measurement accuracy.
  • Handling Precautions:
    • Avoid prolonged exposure to silicones, HMDS, lead compounds, sulfur compounds and other catalyst poisons.
    • Avoid contact with organic solvents, alcohol, paints and oils.
    • Do not exceed rated operating voltage/current to prevent catalyst damage.
    • Calibrate with standard gas in clean air background with stable, gentle gas flow.