GASSHIELD UGT-C5 Combustible Gas Sensor

No.UGT-C5
Catalytic combustion combustible gas sensor. 0-100%LEL, ±3% accuracy, T90<10s, 5-year life. Φ12×8mm, DC 2.5V, 26-34mV/20%LEL. Excellent poisoning resistance.
  • GASSHIELD UGT-C5 Combustible Gas Sensor
  • GASSHIELD UGT-C5 Combustible Gas Sensor
  • GASSHIELD UGT-C5 Combustible Gas Sensor
  • GASSHIELD UGT-C5 Combustible Gas Sensor
  • GASSHIELD UGT-C5 Combustible Gas Sensor
  • GASSHIELD UGT-C5 Combustible Gas Sensor
  • GASSHIELD UGT-C5 Combustible Gas Sensor
  • GASSHIELD UGT-C5 Combustible Gas Sensor
  • GASSHIELD UGT-C5 Combustible Gas Sensor

Description

1. Product Overview

The GASSHIELD UGT-C5 is a high-performance catalytic combustion-type combustible gas sensor designed for accurate and reliable detection of Methane (CH₄), Propane (C₃H₈), Butane (C₄H₁₀) and most combustible gases and vapors. With a detection range of 0–100% LEL, output sensitivity of 26–34 mV at 20% LEL methane, and rapid T90 < 10 s response time, the UGT-C5 delivers fast, precise combustible gas detection for safety-critical applications.
The sensor operates on the proven catalytic combustion principle with a Wheatstone bridge circuit, providing superior linearity (±3%), excellent repeatability and 5-year operating life in clean air. With strong vibration resistance, excellent poisoning resistance and stable output across −40°C to +70°C, the compact Φ12 mm UGT-C5 is ideal for integration into portable gas detectors, fixed gas alarm controllers, industrial safety systems and smart gas leak detection devices.

2. Technical Principle

The UGT-C5 employs a catalytic combustion (pellistor) detection principle. The sensor consists of a matched pair of elements — a catalytic (detection) element and a reference (compensation) element — arranged in a Wheatstone bridge circuit.
When combustible gas diffuses into the sensor and contacts the catalytic element, it oxidizes on the heated catalyst surface, causing a rise in element temperature and resistance. The reference element, coated with inert material, remains unaffected by the gas, compensating for ambient temperature and humidity variations. The resulting resistance imbalance in the bridge generates a voltage output proportional to the gas concentration, delivering a linear response from 0 to 100% LEL.
The sensor exhibits excellent directional stability: when rotated 360° in the vertical direction, the output signal change is limited to ±0.5% LEL, ensuring consistent readings regardless of installation orientation.

3. Key Features & Competitive Advantages

A. Superior Linearity & Accuracy

  • Detection accuracy of ±3% LEL with full-scale deviation of only ±5% FS.
  • Linearity of ±3% across 0–100% LEL (calibrated at 60% LEL).

B. Fast Response & Recovery

  • T90 < 10 s at 50% LEL methane for rapid leak detection.
  • Recovery time of only 15 s, enabling continuous monitoring cycles.

C. Good Long-Term Working Stability

  • 5-year operating life in clean air with minimal output drift.
  • 2-year warranty from date of shipment.

D. Excellent Poisoning Resistance

  • Outstanding resistance to silicon poisoning (HMDS), maintaining >95% output after 60 min at 20 ppm HMDS exposure.

E. Strong Vibration Resistance

  • Robust construction withstands mechanical vibration in industrial and vehicle-mounted applications.

F. Excellent Repeatability

  • Consistent output signal with tight batch-to-batch uniformity.

G. Wide Operating Environment

  • Operating temperature: −40°C to +70°C.
  • Continuous humidity: 15–90% RH (non-condensing); intermittent: 0–99% RH.
  • Low power consumption: <500 mW.

H. Compact Size, Cost-Effective

  • Φ12 mm compact form factor for space-constrained instrument designs.
  • Cost-effective solution for OEM manufacturers.

4. Technical Specifications

Parameter Specification
Detection Performance
Target Gas Most combustible gases and vapors
Detection Principle Catalytic combustion
Detection Range 0 ~ 100% LEL
Detection Accuracy ±3% LEL
Zero Drift ±1% LEL
Full-Scale Deviation ±5% FS
Linearity ±3% (0–100% LEL, 60% LEL calibrated)
Response Time T90 < 10 s (50% LEL Methane)
Recovery Time 15 s
Sensitivity Output 26–34 mV / 20% LEL Methane
Zero Output ±20 mV
Operating Life 5 years (in clean air)
Warranty 2 years (from date of shipment)
Electrical Characteristics
Operating Voltage DC 2.5 ± 0.1 V
Operating Current (at 2.5V) 170 ~ 190 mA
Power Consumption < 500 mW
Detection Circuit Wheatstone bridge (Vin+/Vin−, Vout+/Vout−)
Operating Environment
Operating Temperature −40 ~ +70 °C
Operating Humidity 15–90% RH continuous, 0–99% RH intermittent (non-condensing)
Storage Environment
Storage Temperature −20 ~ +50 °C
Storage Humidity ≤95% RH (non-condensing)
Physical
Dimensions Φ12 mm × 13 mm (8 mm + 5 mm), pin Φ0.75 mm
Directional Characteristic Output change ≤ ±0.5% LEL at 360° vertical rotation
Relative Sensitivity to Common Gases (%): Methane 100 | Ammonia 98 | Hydrogen 70 | Methanol 70 | Ethane 69 | Ethylene 69 | Propane 60 | Ethanol 52 | Butane 44 | Hexane 42 | Acetone 42 | Isobutane 42 | Butanone 40 | Dimethyl ether 39 | Diethyl ether 38 | Heptane 38 | Cyclohexane 37 | Ethyl acetate 37 | Octane 37 | Toluene 35 | Pentane 35 | n-Octane (Gasoline) 35 | Acetic acid 35 | Xylene 26
Note: Relative sensitivity values may vary with production batch and test environment. Calibrate with the target gas before use.

5. Applications

The GASSHIELD UGT-C5 is engineered for versatile deployment across combustible gas detection and safety monitoring scenarios:
  • Instrumentation: Core sensing element for combustible gas analyzers, detectors and alarm controllers.
  • Industrial Safety: Fixed and portable gas detection systems for oil & gas, petrochemical and chemical processing facilities.
  • Gas Leak Detection: Early warning systems for natural gas (methane) and LPG (propane/butane) leaks in pipelines, storage tanks and distribution equipment.
  • Smart Home & Municipal: Residential and commercial natural gas/LPG leak alarms for smart home and smart city projects.
  • Commercial & Catering: Kitchen gas leak detection in restaurants, hotels and canteens.
  • Wastewater & Environmental: Methane monitoring in sewage treatment plants, landfills and biogas facilities.
  • Mining & Tunnels: Combustible gas monitoring in coal mines, underground tunnels and confined spaces.

6. OEM Integration & Design Guidelines

To maximize design flexibility and ensure optimal sensor performance, the UGT-C5 is supported by comprehensive integration resources and handling guidelines for equipment manufacturers.
  • Basic Circuit Reference: Standard Wheatstone bridge circuit (Vin+/Vin− power input, Vout+/Vout− differential output) with recommended reference detection circuit provided for immediate PCB design integration. Operating voltage: DC 2.5 ± 0.1 V.
  • Temperature Compensation: See Section 5.2 for the temperature response curve (−40°C to +70°C, zero-compensated) to guide firmware compensation algorithms.
  • Humidity Compensation: See Section 5.3 for humidity response data (20–95% RH) for environmental robustness design.
  • Response & Recovery Characterization: See Sections 5.1 and 5.6 for gas response and long-term drift data to optimize alarm thresholds and calibration intervals.
  • Gas-Specific Calibration: Use the Relative Sensitivity Table (Section 4) to convert readings between calibration gas and target gas: Detector reading = calibration gas concentration × (calibration gas coefficient ÷ target gas coefficient). Calibrate with the target gas before use; cross-sensitive gas calibration cannot guarantee measurement accuracy.
  • Handling Precautions:
    • Avoid prolonged exposure to silicones, HMDS, lead compounds, sulfur compounds and other catalyst poisons.
    • Avoid contact with organic solvents, alcohol, paints and oils.
    • Do not exceed rated operating voltage/current to prevent catalyst damage.
    • Calibrate with standard gas (e.g., 50% LEL methane) in clean air background with stable, gentle gas flow.